Post Top Ad

Thursday, October 19, 2023

on video SSR Connection With Selector Switch | What is Solid State Relay


 What is Solid State Relay? Construction, Operation, Applications & Types of SSR Relays

In this article, we will briefly discuss the SSR (Solid State Relay), its construction, operation, Schematics & different types of SSR relays based on its switching property and input/output forms. We will also discuss the advantages & disadvantages of Solid State Relay (SSR) comparing to Electromagnetic Relays (EMR) relay.

What is Solid State Relay (SSR)?

Solid state relay (SSR) is an electronic switching device made of semiconductors that switch (On & Off) a high voltage circuit using a low voltage at its control terminals.


Unlike EMR (Electromagnetic relay) that has a coil & mechanical switch (physical contacts), the SSR relay uses Optocoupler to isolate the control circuit from the controlled circuit.



Difference between SSR & EMR

The operation of SSR (Solid State Relay) and EMR (Electromagnetic Relay) or contact relay is the same while the main difference between SSR and EMR is that there are no mechanical parts and contacts in SSR relay. Normally, SSR has 1a contact while EMR having multiple contacts.


Other difference between Solid State Relay and Electromagnetic relay are that there is no surge and noise during the operation of SSR. There is a chance of leakage current about a few μA to mA in SSR relay while the value of leakage current is Zero (0) in EMR. At the other hand, SSR switch OFF AC loads at the point of 0 load current which leads to eliminating the noise, contact bounce and electrical arcing in case of inductive load as compared to EMR relays.

Related Post: Difference Between Relay and Circuit Breaker

Construction of SSR (Solid State Relay)

Terminals Of SSR Relay

SSR relay has two sets of terminals i.e. input terminals & output terminals. These terminals are given below:


Input Or Control Terminals

These two terminals are the input control terminal. It is connected to a low power circuit that controls its switching.



The control input of an SSR relay is designed for DC or AC circuit separately.


The Output Normally Open (NO) Terminals

The output terminals of SSR relay switches on and off depending on the control input.


Normally, the electrical connection between these terminals remains open. When the relay activates, these terminals connect together providing a closed path.


The output terminals are specifically designed for either AC or DC circuit. Unlike EMR relay, an SSR relay cannot switch both AC & DC signal using the same terminals.


Related Post: Different Types of Sensors with Applications

Output Normally Closed (NC) Terminal

This terminal of the relay remains closed until the relay is activated. There is no current flow when the relay activates. It becomes open upon activation of the relay.

NOTE: Commonly used SSR relays have no NC (normally closed) terminals. But Form B & Form C SSR relay (discussed below) uses NC terminal.


Operation & Working of SSR Relay

When a low voltage is applied to the input control terminals of the SSR relay, the output Load terminals become electrically short.


The input of the SSR relay activates the optocoupler which switches the Load circuit. The optocoupler has no physical connection & it isolates the low voltage circuit from the high voltage circuit.

Optocoupler has an LED at its input which emits infrared light when a voltage is applied. These IR waves are received by the photo-sensor (Photo-transistor, photodiode etc.) on its output end. The Photo-sensor converts the light signal into an electrical signal & switches on the circuit.



To activate the optocoupler, its input voltage should be greater than its forward voltage. Due to this reason, SSR relays do not activate on lower voltage than its specified voltage.


The output circuitry of SSR relay varies for AC & DC circuits. It is usually made up of TRIAC or Thyristors for AC circuit & Power MOSFETs for DC circuit.


Related Post: Types of Diodes and Their Applications

Schematic Model of SSR Relay

A general schematic for the operation of a DC to AC SSR relay’s operation with model schematic is given below:

A DC input of sufficient voltage is applied at the control input terminals. There is a diode for protection against the reverse polarity of the applied DC.



When the voltage is applied to the LED of the optocoupler, it emits infrared light.


On the other end, the Opto-TRIAC (receiver) picks up the light & switches on. As soon as the optocoupler switches on, the output AC current starts flowing through it


In turn, this optocoupler’s output activates the TRIAC. Thus allowing the flow of AC Load Circuit current


Related Post: Types of Switches. Its Construction, Working & Applications

Types Of SSR Relay

There are different types of SSR (Solid State) relays. They are either classified on their Input/output form or their switching property.

Classification Based On Input/Output

Following are some of the common types of SSR relay classified based on its input & output circuit (AC/DC).



DC-To-AC SSR Relay

This relay Operates on DC input to switch an AC Load Circuit. The control input of this SSR relay operates only on DC input.


The fact that this relay does not operate on AC input is because optocoupler operates on DC. Its input terminals are also directional. Reversing the polarity of the input will not activate the relay. There is a diode used for protection against the reverse polarity of the input.

Even after applying the required input, the output switch of this SSR does not activate but only when AC voltage is applied to its output terminals.


Following is the schematic of a DC-TO-AC SSR relay.


Related Post: Types of Transformers and Their Applications


AC-To-AC SSR Relay

The SSR relay operates only when the Input and output both circuits are AC.


As we know, the optocoupler operates on DC voltage. So a rectifier is used before the optocoupler to convert AC to DC.


When sufficient AC voltage is applied to its input control terminal, it activates providing the flow of AC load current.


Its schematic is given below.

DC-To-DC SSR Relay

This relay can switch High power DC load using a low power DC source.


The DC input is applied to the optocoupler as described in the other example above.


However, to switch a DC load, a power MOSFET or IGBT is used.

The Mosfet conducts current in only one direction so it is also necessary to make sure the output load is connected using correct polarity. A protection diode is used to avoid damage during reverse polarity.


If there is an inductive load, a freewheeling diode should be used with the load.


DC-To-AC/DC SSR Relay

This type of SSR relay can switch AC & DC load using separate terminals.


Such kind of SSR relay uses MOSFETs in series with common Source terminals for switch both AC & DC circuit.


Its schematic is given below.

This schematic shows a photodiode cell array as a light sensor which produces a voltage when the LED activates. This voltage is applied to the gates & source of the N-MOSFETs connected in series.


To use this relay for AC circuit, the Drain terminals of MOSFETs are used & the source terminals should remain unused.


While using DC circuit, Drain & source terminal of the MOSFETs are used for switching.


Related Post: Types of Fuses – Its Construction, Operation & Applications

Classification Based On Switching Property

SSR relays are also classified based on their switching properties which are given below.


These relays control AC circuits and are used to control the desired outputs in a specific application


Instant ON SSR Relay

Such type of relay instantly switches on the load circuit whenever a sufficient input voltage is applied. It switches off upon the next zero crossing of load voltage after the removal of the control input.


Zero Switching SSR Relay

This kind of relay switches on when an input voltage is applied and the load AC voltage crosses the next zero voltage.


It turns off like normal SSR relays when the input voltage is removed and the load AC voltage reaches zero volts.


The operation for zero switching relay is achieved by a circuit known as zero crossing circuit, which detects the zero crossing and activates the TRIAC.

Peak Switching SSR Relay

These types of SSR relay switches on when the output AC voltage hits its next peak after applying the required input control voltage.


It also turns off after the removal of the input voltage and the zero crossing of the output AC current.


There is a peak detection block used in these relays, which fires the TRIAC when the output AC cycle hits its peak.


Analog Switching SSR Relay

While these other types of SSR’s switching depend on output AC cycle, this relay’s switching depends on its input amplitude.


The starting output voltage of analog SSR relay is proportional to the input control voltage.


Suppose 3-32v DC input relay’s 3v represents 0% & 32v represent 100% of the load AC peak voltage.


When the control input is removed the relay switches off upon the next output AC zero crossing.

Related Post: Types of Resistors | Fixed, Variable, Linear & Non-Linear

Classification Based On Poles & Throw

SSR relays are classified into three types or “Forms” considering their poles & throw configuration.


Form A Or SPST NO Type SSR

Form A type of SSR relay is SPST (Single Pole Single Throw) relay with normally open (NO) terminals. The output load terminals are normally open when there is no external control input. When the relay activates, the output terminals connect together & allows the flow of current.


The diagram below shows an SSR relay capable of switching AC & DC on separate terminals.


 What is Solid State Relay? Construction, Operation, Applications & Types of SSR Relays

In this article, we will briefly discuss the SSR (Solid State Relay), its construction, operation, Schematics & different types of SSR relays based on its switching property and input/output forms. We will also discuss the advantages & disadvantages of Solid State Relay (SSR) comparing to Electromagnetic Relays (EMR) relay.

What is Solid State Relay (SSR)?

Solid state relay (SSR) is an electronic switching device made of semiconductors that switch (On & Off) a high voltage circuit using a low voltage at its control terminals.


Unlike EMR (Electromagnetic relay) that has a coil & mechanical switch (physical contacts), the SSR relay uses Optocoupler to isolate the control circuit from the controlled circuit.



Difference between SSR & EMR

The operation of SSR (Solid State Relay) and EMR (Electromagnetic Relay) or contact relay is the same while the main difference between SSR and EMR is that there are no mechanical parts and contacts in SSR relay. Normally, SSR has 1a contact while EMR having multiple contacts.


Other difference between Solid State Relay and Electromagnetic relay are that there is no surge and noise during the operation of SSR. There is a chance of leakage current about a few μA to mA in SSR relay while the value of leakage current is Zero (0) in EMR. At the other hand, SSR switch OFF AC loads at the point of 0 load current which leads to eliminating the noise, contact bounce and electrical arcing in case of inductive load as compared to EMR relays.

Related Post: Difference Between Relay and Circuit Breaker

Construction of SSR (Solid State Relay)

Terminals Of SSR Relay

SSR relay has two sets of terminals i.e. input terminals & output terminals. These terminals are given below:


Input Or Control Terminals

These two terminals are the input control terminal. It is connected to a low power circuit that controls its switching.



The control input of an SSR relay is designed for DC or AC circuit separately.


The Output Normally Open (NO) Terminals

The output terminals of SSR relay switches on and off depending on the control input.


Normally, the electrical connection between these terminals remains open. When the relay activates, these terminals connect together providing a closed path.


The output terminals are specifically designed for either AC or DC circuit. Unlike EMR relay, an SSR relay cannot switch both AC & DC signal using the same terminals.


Related Post: Different Types of Sensors with Applications

Output Normally Closed (NC) Terminal

This terminal of the relay remains closed until the relay is activated. There is no current flow when the relay activates. It becomes open upon activation of the relay.

NOTE: Commonly used SSR relays have no NC (normally closed) terminals. But Form B & Form C SSR relay (discussed below) uses NC terminal.


Operation & Working of SSR Relay

When a low voltage is applied to the input control terminals of the SSR relay, the output Load terminals become electrically short.


The input of the SSR relay activates the optocoupler which switches the Load circuit. The optocoupler has no physical connection & it isolates the low voltage circuit from the high voltage circuit.

Optocoupler has an LED at its input which emits infrared light when a voltage is applied. These IR waves are received by the photo-sensor (Photo-transistor, photodiode etc.) on its output end. The Photo-sensor converts the light signal into an electrical signal & switches on the circuit.



To activate the optocoupler, its input voltage should be greater than its forward voltage. Due to this reason, SSR relays do not activate on lower voltage than its specified voltage.


The output circuitry of SSR relay varies for AC & DC circuits. It is usually made up of TRIAC or Thyristors for AC circuit & Power MOSFETs for DC circuit.


Related Post: Types of Diodes and Their Applications

Schematic Model of SSR Relay

A general schematic for the operation of a DC to AC SSR relay’s operation with model schematic is given below:

A DC input of sufficient voltage is applied at the control input terminals. There is a diode for protection against the reverse polarity of the applied DC.



When the voltage is applied to the LED of the optocoupler, it emits infrared light.


On the other end, the Opto-TRIAC (receiver) picks up the light & switches on. As soon as the optocoupler switches on, the output AC current starts flowing through it


In turn, this optocoupler’s output activates the TRIAC. Thus allowing the flow of AC Load Circuit current


Related Post: Types of Switches. Its Construction, Working & Applications

Types Of SSR Relay

There are different types of SSR (Solid State) relays. They are either classified on their Input/output form or their switching property.

Classification Based On Input/Output

Following are some of the common types of SSR relay classified based on its input & output circuit (AC/DC).



DC-To-AC SSR Relay

This relay Operates on DC input to switch an AC Load Circuit. The control input of this SSR relay operates only on DC input.


The fact that this relay does not operate on AC input is because optocoupler operates on DC. Its input terminals are also directional. Reversing the polarity of the input will not activate the relay. There is a diode used for protection against the reverse polarity of the input.

Even after applying the required input, the output switch of this SSR does not activate but only when AC voltage is applied to its output terminals.


Following is the schematic of a DC-TO-AC SSR relay.


Related Post: Types of Transformers and Their Applications


AC-To-AC SSR Relay

The SSR relay operates only when the Input and output both circuits are AC.


As we know, the optocoupler operates on DC voltage. So a rectifier is used before the optocoupler to convert AC to DC.


When sufficient AC voltage is applied to its input control terminal, it activates providing the flow of AC load current.


Its schematic is given below.

DC-To-DC SSR Relay

This relay can switch High power DC load using a low power DC source.


The DC input is applied to the optocoupler as described in the other example above.


However, to switch a DC load, a power MOSFET or IGBT is used.

The Mosfet conducts current in only one direction so it is also necessary to make sure the output load is connected using correct polarity. A protection diode is used to avoid damage during reverse polarity.


If there is an inductive load, a freewheeling diode should be used with the load.


DC-To-AC/DC SSR Relay

This type of SSR relay can switch AC & DC load using separate terminals.


Such kind of SSR relay uses MOSFETs in series with common Source terminals for switch both AC & DC circuit.


Its schematic is given below.

This schematic shows a photodiode cell array as a light sensor which produces a voltage when the LED activates. This voltage is applied to the gates & source of the N-MOSFETs connected in series.


To use this relay for AC circuit, the Drain terminals of MOSFETs are used & the source terminals should remain unused.


While using DC circuit, Drain & source terminal of the MOSFETs are used for switching.


Related Post: Types of Fuses – Its Construction, Operation & Applications

Classification Based On Switching Property

SSR relays are also classified based on their switching properties which are given below.


These relays control AC circuits and are used to control the desired outputs in a specific application


Instant ON SSR Relay

Such type of relay instantly switches on the load circuit whenever a sufficient input voltage is applied. It switches off upon the next zero crossing of load voltage after the removal of the control input.


Zero Switching SSR Relay

This kind of relay switches on when an input voltage is applied and the load AC voltage crosses the next zero voltage.


It turns off like normal SSR relays when the input voltage is removed and the load AC voltage reaches zero volts.


The operation for zero switching relay is achieved by a circuit known as zero crossing circuit, which detects the zero crossing and activates the TRIAC.

Peak Switching SSR Relay

These types of SSR relay switches on when the output AC voltage hits its next peak after applying the required input control voltage.


It also turns off after the removal of the input voltage and the zero crossing of the output AC current.


There is a peak detection block used in these relays, which fires the TRIAC when the output AC cycle hits its peak.


Analog Switching SSR Relay

While these other types of SSR’s switching depend on output AC cycle, this relay’s switching depends on its input amplitude.


The starting output voltage of analog SSR relay is proportional to the input control voltage.


Suppose 3-32v DC input relay’s 3v represents 0% & 32v represent 100% of the load AC peak voltage.


When the control input is removed the relay switches off upon the next output AC zero crossing.

Related Post: Types of Resistors | Fixed, Variable, Linear & Non-Linear

Classification Based On Poles & Throw

SSR relays are classified into three types or “Forms” considering their poles & throw configuration.


Form A Or SPST NO Type SSR

Form A type of SSR relay is SPST (Single Pole Single Throw) relay with normally open (NO) terminals. The output load terminals are normally open when there is no external control input. When the relay activates, the output terminals connect together & allows the flow of current.


The diagram below shows an SSR relay capable of switching AC & DC on separate terminals.